SDB-1-2220-AL | 3~480V | 22 kW-30 HP-41A | S3

Clean Power Variable Frequency Drive, input 3x 480V, rated output 41A, IP20, embedded AFE

Main features

  • Variable frequency drive for AC motors
  • Pure sine wave 3-phase power output
  • Clean Voltage sine wave, V/f open and close loop
  • Field Oriented Control open and close loop
  • Multifunctional, digital and analog IOs
  • Built-in torque deactivation inputs
  • 24 VDC power supply input
  • Dual Ethernet port
  • Fire emergency mode
  • Configurable Linear ramps
  • Starting torque boost
  • Integrated EMC filters
  • Set, monitor, control it with an app
  • Pluggable display
  • Natural language user interface

Download the product datasheet:

PDF download icon

Description

The SmartD Clean Power Variable Frequency Drive is a compact AC drive utilizing SmartD’s patented own algorithms combined with WBG transistor technology. Producing a clean and pure sine wave to power and control 3-phase AC induction motors has never been easier. The SmartD VFD has essential features built-in for space, wiring and time savings, it eliminates the need for filters on the output, and guarantees longer motor lifetime.

Cette publication est également disponible en : English

SDB-1-2220-AL | 3~480V | 22 kW-30 HP-41A | S3 specs

Product functionVariable frequency drive for AC motors
Controlled motorsAsynchronous 3-phases motors
Control MethodsClean Voltage sine wave, V/f open and close loop.
indirect Field Oriented Control (iFOC) open and close loop
Input Power VoltageVAC3 ~ 400 -15% / +10%
3 ~ 480 -15% / +10%
Input Power FrequencyHz50 and 60 +/- 5%
Input line currentA rmsRated at 40 °C (104 °F)43
Apparent powerkVA@ 480V38
Prospective Line IsckA50
THDi%< 5  from 50…100 % of load conforming to IEC 61000-3-12
Output CurrentA rmsNormal operation (continuously available without overload) at 40 °C (104 °F)41
Heavy duty operation at 40 °C (104 °F)35
Motor Power kW normal duty (1)3x400VAC 50/60Hzmax 22KW
Motor Power kW heavy-duty (1)max 18.5kW
Motor Power HP normal duty (1)30 HP
Motor Power HP heavy-duty (1)25HP
Motor Power kW normal duty (1)3x460VAC 50/60Hzmax 22KW
Motor Power kW heavy-duty (1)max 18.5kW
Motor Power HP normal duty (1)30HP
Motor Power HP heavy-duty (1)25 HP
Motor Power kW normal duty (1)3x575VAC 50/60Hz
Motor Power kW heavy-duty (1)
Motor Power HP normal duty (1)
Motor Power HP heavy-duty (1)
(1) motor power values are indicative. They vary depending on the motor type, technology, and manufacturer.
The variable frequency drive must not be selected from the motor power rating
The variable frequency drive must be selected by skilled and experienced personnel.
The variable frequency drive must be selected according to motor FLA, the load’s driving force, the movement cycle, and the operating environment.
Maximum Transient Output currentA rmsNormal operation46 during 60s every 10 min at 40 °C (104 °F)
A rmsHeavy duty operation53 during 60s every 10 min at 40 °C (104 °F)
Permissible temporary current boost
(motor starting)
A rmsNormal operation≤ 82 at 40 °C (104 °F) during 2s
A rmsHeavy duty operation≤ 82 at 40 °C (104 °F) during 2s
Short-circuit current for immediate trippingA peak≥ 116 at 40 °C (104 °F)
Output Frequency range of the drivekHz0.001 to 0.5
Speed drive output FrequencyHz0.1 to 120
Nominal switching frequencykHz105
effective switching frequencykHz210
efficiency8 points graph as per IEC61800-9≥ 96%
IE Class2
DeratingsAmbient temperature derating-15…40 °C without derating
>40…60 °C , Derate 2% for every 1 °C (1.8 °F)
Altitude deratingno derating up to 2000 m
BrakingRegenerative braking through AFE
Voltage24 VDC
Limits20.4 VDC to 28.8 VDC
Built in protection of auxiliary power inputReverse polarity and overvoltage
Standard to comply withIEC 61131-2 type 1
Digital input numbers6
Digital inputs common terminal1
inputs 1 and 2Settable by userusable for encoder
inputs 3 to 6Settable by usersettable by user
input logicwire-able as sink or source, configurable by software
default: source
Source mode logic thresholdsON: 18 .. 24V / OFF: 0 .. 6V
Sink mode logic thresholdsON: 0 .. 6 V / OFF: 18 .. 24 V
Current consumption6mA
Auxiliary Output power for digital inputs+24VDC (20% .. +20%) / 100 mA
Built-in protection of Auxiliary output powerovercurrent and overvoltage
STO (Torque deactivation) inputsNumber of STO inputs2
stop categorycategory 0
STO input reaction time< 20 ms
STO input filtering time3 ms
Nominal voltage of STO enabling input24V
Maximum input voltage28.8V
Logic threshold10V (+/- 5V)
Low state maximum voltage
for disable to SIL3 and Ple
5V
Digital output numbers3
relay 1relay output SPDT (form C)NO ContactResistive load, AC: 5 A @ 250 V / DC 5 A @ 30 V
NC ContactResistive load, AC: 3 A @ 250 V / DC 3 A @ 30 V
relay 2 and 3relays output NO (form A)Resistive load, AC: 3 A @ 250 V / DC 3 A @ 30 V

Analog input numbers3
Analog input typessettable by users0..10VDC
0..20mA / 4..20mA
0..24VDC
Impedance to read PTC temperature sensor
Input impedance0..10VDC: input impedance > 3.5 k Ohms
0..20mA / 4..20mA: input impedance 165 Ohms
0..24VDC: input impedance > 3.5 k Ohms
Resolution12 bits
Sampling time2ms
Accuracy± 1% at 25 °C (77 °F) / ± 2% for a temperature variation of 60 °C (108 °F)
Reference power supply for potentiometer+10 VDC / tolerance ± 2% for the temperature range of 20 °C to 30 °C / Current : maximum 10 mA, short circuit protected
Analog output numbers2
Analog output typessettable by users0..10VDC ( ≥ 15 mA)
0..20mA / 4..20mA
Analog output impedances0..10VDC: output impedance 500 Ohms minimum
0..20mA / 4..20mA: output impedance 500 Ohms maximum
Resolution12 bits
Sampling time2 ms
Accuracy± 1% at 25 °C (77 °F) / ± 2% for a temperature variation of 60 °C (108 °F)
Analog outputs built-in protectionovervoltage and overcurrent
Embedded ports on 2 RJ45Modbus TCP

BACnet IP

Wireless for SettingsBLE
Width11.85 in (30.1 cm)
Height25.59 in (65 cm)
Depth9.88 in (25.1 cm)
Net weight66 lb (30 kg)
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…40 °C without derating 40…60 °C with derating factor 2% for every 1 °C (1.8 °F) »
Ambient air temperature for storage-40…70 °C
CoolingIntegrated, replaceable fans
Operating altitude≤ 2000 m without derating
Environmental characteristicChemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
Ingress Protection IPIP20
Protection DegreeUL (NEMA) type 1
Functional safetyUL/IEC 61800-5-1:2007+AMD:2016CSV
EMCIEC 61800-3 : 2017 emissions ; IEC 61000-4 immunity; IEC 61000-4-11 -34 voltage variations
HarmonicsIEC 61000-3-12 ; IEEE 519
GeneriqueIEC 61800-2: 2021
EcoDesign / Energy efficiencyIEC 61800-9
Safety standard ( STO)IEC 61508 part 1 and part2 ; IEC 62061 :2021
Cybersecurity IEC 62443
EnvironmentalIEC 60068-2 ; WEEE directive ; RoHS
CERTIFICATIONSUL

*Les spécifications sont susceptibles de changer sans préavis.

Bénéfices

sine wave

Harmoniques ultra-faibles

Le Clean Power VFD ne crée que de très faibles harmoniques, réduisant le bruit électrique et augmentant l’efficacité énergétique de votre équipement.

filterless

Sans filtre

Le Clean Power VFD n’a pas besoin de filtres, ce qui permet un fonctionnement rentable et sans entretien de votre équipement.

Symbol of IGBT

Active Font End (AFE)

Le Clean Power VFD est doté d’un AFE qui permet d’obtenir un facteur de puissance proche de l’unité, des harmoniques très faibles et un freinage régénératif pour une meilleure efficacité énergétique.

Smaller VFD

Encombrement divisé par 2

Le Clean Power VFD étant de conception compacte et éliminant le besoin de filtres, il permet de gagner jusqu’à 50 % d’espace et de simplifier le câblage de l’équipement.

Sine Wave

Signal propre

Le Clean Power VFD utilise la dernière technologie de composants électroniques de puissance, un algorithme breveté et des filtres intégrés, il produit une onde sinusoïdale propre.

SmartD motor control

Durée de vie prolongée du moteur

Les performances avancées du Clean Power VFD réduisent les contraintes sur l’isolation du moteur, les dommages aux roulements et le bruit électrique, ce qui prolonge la durée de vie du moteur.

// a la poursuite de l'énergie propre

Notre aventure du Clean Power VFD

Cliquez sur l’image pour lire l’histoire

INCEPTION:
Simon Leblond et Simon Caron créent SmartD Technologies Inc, en 2018, à Montreal Quebec.

INNOVATION:
SmartD développe la première technologie de variateur de fréquence (VFD) basée sur des semi-conducteurs à large bande interdite sur le marché - offrant une énergie propre d'une manière inédite. Pour atteindre ce niveau de technologie, SmartD travaille avec certains des spécialistes WBG les plus avancés de l'industrie.

Clean Power VFDs

IMPACT:
PDes partenariats sont établis avec SE Ventures, le Groupe de recherche en électronique de puissance et commande industrielle (GRÉPCI), PME MTL, et la Chaire de recherche du Canada en conversion d’énergie électrique et en électronique de puissance.

SmartD Investors
// SELECTION SIMPLE

Sélection de VFD Simplifiée

Plus simple de A à Z

La facilité commence par le choix du bon produit. La structure de l’offre du Clean Power VFD de SmartD est conçue pour faciliter la décision et éviter les choix complexes entre plusieurs niveaux d’options.

La facilité commence par le choix du bon produit. La structure de l’offre du Clean Power VFD de SmartD est conçue pour faciliter la décision et éviter les choix complexes entre plusieurs niveaux d’options.

Part numbering structure

Réservez une démonstration dès maintenant !

Clean Power VFD de SmartD est une réalité et il est prêt à révolutionner le contrôle des moteurs. Ne vous contentez pas de nous croire sur parole, voyez par vous-même.

// FAQ

Foire aux questions

Qu'est-ce qu'un variateur de fréquence?

Un variateur de Fréquence est un dispositif électronique qui contrôle la vitesse d'un moteur électrique en faisant varier la fréquence et la tension fournies au moteur.

Un variateur de vitesse ajuste la vitesse du moteur en fonction des besoins de la charge entraînée, ce qui permet de réduire considérablement la consommation d'énergie.

Un VFD, ou "Variable Frequency Drive" en anglais, est appelé couramment Variateur de vitesse, ou Variateur de fréquence, ou Convertisseur de fréquence dans les industries francophones .

Pourquoi le VFD Clean Power est-il le bon choix?

Le variateur de fréquence Clean Power de SmartD génère des signaux électriques sinusoïdaux purs dans un volume deux fois plus petit et deux fois plus efficace.

Oubliez les câbles encombrants et les filtres volumineux. Faites l'expérience de la puissance propre dans un encombrement compact.

Combien de temps faut-il pour installer le variateur de fréquence SmartD Clean Power?

3 câbles en entrée, 3 câbles en sortie. C'est tout Installez-le et laissez-le faire son travail en moins de 30 minutes.

Le SmartD Clean Power VFD fonctionnera-t-il avec nos systèmes existants?

Nos produits sont prêts pour l'IoT, la GTB et le SCADA.
Connectivité Ethernet et Modbus pour l'intégration aux systèmes Cloud, BMS et SCADA.

Le SmartD Clean Power VFD est-il disponible à l'achat?

Le SmartD Clean Power VFD sera disponible à l'achat au troisième trimestre 2022.

SmartD Clean Power VFD