Low Harmonics to the Grid. True Sinewave to the Motor

Instead of adding external filters and special motor protection, our SiC-based architecture delivers clean power at the source—fewer components, less stress, more predictable performance.

ABOUT

The Clean Power VFD was built to solve the problems conventional drives create.

Instead of adding external filters and special motor protection, our SiC-based architecture delivers low harmonics to the grid and a true sinewave to the motor—at the source. Fewer components. Less stress on equipment. More predictable performance.

Get in Touch with our Team

If you’re planning a retrofit or new installation, we’re happy to review your application and see if it’s the right fit.

The Evolution of Motion: From Invention to Clean Power

1834

The Birth of the Motor

The first practical electric motors emerge, converting electrical energy into mechanical work and powering the Industrial Revolution.

1888

The AC Revolution

Nikola Tesla patents the AC induction motor. Rugged, simple, and efficient — but with one major limitation: fixed speed. For nearly a century, speed control remains mechanical and inefficient.

1960s

The Dawn of the VFD

The first Variable Frequency Drives (VFDs) arrive. For the first time, AC motor speed can be controlled electronically by manipulating frequency — but it introduces a hidden tradeoff.

The Industry Response

To protect equipment, manufacturers add mitigation devices — sinewave filters, line reactors, common-mode chokes, specialized VFD cables. Motor control advances, but complexity multiplies.

2018

The SmartD Breakthrough

SmartD rethinks motor control using Silicon Carbide (SiC) technology and multi-level power conversion.

Instead of mitigating the damage, we eliminate it at the source — delivering low harmonics to the grid and a true sinewave to the motor. No bulky external filters. No layered fixes.

2026

Global Impact & Proven Performance

Today, SmartD Clean Power VFDs operate in hundreds of installations worldwide — from heavy industrial facilities to municipal infrastructure and commercial agriculture.

They deliver low harmonic distortion, near-unity power factor, and motors that run cooler and last longer — without external mitigation equipment.

OUR PRODUCTS

SmartD Clean Power VFDs combine SiC technology, active front end architecture, and integrated filtering to deliver < 3% THDi on the line side and a true sinewave on the motor side — in one compact drive. No mitigation layers. No added complexity. Just clean power.

Not every application requires a Clean Power VFD. Share a few details about your project, and we’ll review whether it makes technical and economic sense.

Clean Power VFD Frame size S3

S3 Series — 10–30 HP

Compact Clean Power VFD designed for small-to-mid horsepower applications.

 

Ideal for pumps, fans, and process equipment requiring low harmonics and true sinewave output — without external filters.

 

Small footprint. Simplified installation. Standard motor and cable compatible.

S4 Series — 30–75 HP

Built for demanding industrial environments where reliability and grid compliance matter.

 

Delivers <5% THDi on the line side and pure sinewave output to the motor — even over long cable runs.

 

Reduced panel space. Lower motor stress. No layered mitigation equipment.

Clean Power VFD Frame size S4

Retrofits

Upgrade your motor control without replacing motors, cables, or transformers.

 

Clean Power architecture is compatible with standard motors and standard cables — even in space-constrained electrical rooms.

 

Simpler commissioning. Predictable performance. Lower total project risk.

Built-In Connectivity

Dual Ethernet ports with support for:

  • I/O control
  • Modbus TCP
  • BACnet IP
  • Local operation

Designed for seamless integration into BMS, SCADA, and industrial networks — without additional gateway hardware.

WHY CLEAN POWER VFD?

Ultra Low Harmonics

Clean Power VFD offers ultra-low harmonics, reducing electrical noise and increasing energy efficiency for your equipment.

Filter-less

Clean Power VFD is filter-less, providing cost-effective and maintenance-free operation for your equipment.

Active Front End

Clean Power VFD features an active front end, enabling power factor near unity, ultra-low harmonics and regenerative braking for improved energy efficiency.

Space divided by 2

Clean Power VFD being of compact design, and eliminating the need for filters, saves up to 50% of space and simplifies equipment wiring.

Clean Signal

Clean Power VFD using the last technology of electronic power components, patented algorithm and embedded filters, it provides motors with a clean sine wave.

Extended Motor Life

Clean Power VFD’s advanced performances reduce motor insulation stress, bearing damage, and electrical noise for a longer motor lifetime.

APPLICATIONS

Water & Wastewater

From lift stations and booster pumps to aeration blowers and sludge handling systems, water and wastewater facilities depend on reliable motor control in electrically sensitive environments. SmartD Clean Power VFDs minimize harmonics at the source and deliver a true sinewave to the motor, reducing transformer heating, nuisance trips, and motor stress — even over long cable runs common in pump stations. Ideal for retrofit projects where space is limited and compliance with IEEE 519 at the PCC is critical.

Data Centers

Data centers demand power quality, stability, and predictable performance. Cooling towers, CRAH/CRAC units, condenser pumps, and chilled water systems must operate without introducing harmonic distortion or electrical noise into sensitive infrastructure. SmartD’s low THDi active front end and pure sinewave output help protect upstream transformers and downstream motors while maintaining near-unity power factor — reducing electrical penalties and lowering infrastructure stress in mission-critical environments.

HVACR

Commercial and institutional HVAC systems rely on fans, pumps, and compressors operating across varying loads. Traditional PWM drives can introduce harmonics and voltage spikes that shorten motor life and increase maintenance costs. SmartD Clean Power VFDs provide precise speed control with low harmonic distortion and reduced motor heating, allowing standard motors and cables to be used without external sine filters — simplifying installations in space-constrained mechanical rooms.

Oil & Mining

Mining operations and oil & gas facilities often operate in remote, harsh, and generator-driven environments where power quality and reliability are essential. Long motor cable runs, heavy loads, and fluctuating supply conditions increase the risk of voltage spikes and bearing damage. SmartD’s integrated sinewave output and low-harmonic front end reduce electrical stress on motors and upstream equipment while eliminating the need for bulky mitigation hardware — improving reliability and reducing maintenance in demanding conditions.

Food & Beverage

Food and beverage plants require reliable, hygienic, and space-efficient electrical systems for pumps, conveyors, mixers, refrigeration compressors, and packaging lines. Electrical noise and harmonic distortion can disrupt sensitive automation equipment and increase transformer heating. SmartD Clean Power VFDs reduce harmonic impact on the facility grid and deliver smooth motor operation, supporting cleaner electrical rooms, reduced maintenance, and longer motor life — without adding external filter cabinets.

This post is also available in: Français